VEGA 301 - STRESS TEST SYSTEM

Previous Next
Im Interested in this Product. Submit Inquiry

VEGA 301 - STRESS TEST SYSTEM

Last Updated on : 10-1-2017

Vega 301 stress test system

ECG Acquisition & Transmission Unit

  1. Compact, light weight and user friendly acquisition unit.
  2. Bluetooth enabled wireless ECG transmission.
  3. Eliminates noise and gives distortion tree ECG.
  4. User programmable treadmill protocols.
  5. In-built rechargeable battery.
  6. Battery status indications.
  7. USB compatibility with computer system

TREADMILL

  1. Provides smooth power & accuracy even at slow speeds and for patient up to 250kg.
  2. Equip with digitally controlled drive system that delivers great performance, improved accuracy and increased relibility
  3. Deliver high torque for even at lower speeds which ensure no log when toot strikes the belt.
  4. Requires minimal maintenance & experience les

SPECIFICATIONECG ACQUISITION, TRANSMISSION  DEVICE

  1. Dimension : 2.6*6.7*12.3 cm
  2. Weight : 160 gms
  3. Power source : Li-ion battery 3.7v, 700mAH
  4. Battery backup : 10 hrs
  5. Battery charging time : 4hrs
  6. Battery charget : input : 220v=10%, 50Hz, output, 6v

TREADMILL

  1. Speed : 0.1 to 9.3 mph (upto 1.5 mph optional)
  2. Elevation : 0 to 22%
  3. Belt drive motor power : 3HP
  4. Safety : optical isolation, emergency stop
  5. Communication : RS 232
  6. User weight capacity : 250kg
  7. Walking area : 1.321*508 mm
  8. Dimension : 1900*710*1200 mm (L*W*H)
  9. Weight : 120kg
  10. Power Requirements : 200 to 240 VAC 50Hz & single phase 10Ampetes
  11. Cart dimension : 1060(H)*815(W)*460(D)mm
  12. Accessories : patient cable, Electrodes, A4 size paper operation manual, software CD
  13. Minimum computer configuration : Operating system : Windows XP and windows 7, processor p4 or higher, ports, USB & serial memory 1GB or higher monitor : 17'', HDD 40 GB(mm), i/o CD-RW peripherals : keyboard, Mouse :& printer 

ACQUISITION, TRANSMISSION & PROCESSING

  1.   Acquisition : simultaneous 12 leads, 14 bits
  2.   Data transmission band : 24-2.48GHz 
  3.   Sampling rate : 300/sec/channel
  4.   input impedence : > 100db
  5.   Time constant : 3.2sec
  6.   CMRR : >100db
  7.   Patient leakage : < 10 A
  8.   Frequency Response : 0.05Hz to 100Hz
  9.   Digital filters : 50 Hz, music tremor 20, 35 or none
  10.   Base line correction : DSP technique to remove ECG wandering
  11.   Calculated parameters : ST-level, ST-slope, HR, METS, Axis etc.
  12.   Fiducial points : Auto/Manual
  13.   Enlarged median lead : configuration
  14.   Median update interval : 6 beats, updated every second 
  15.   Protocols : Bruce, medified bruce, balke, ellested naughton & customisec protocols can be created

DISPLAY

  1. Display resolution : 1024*768 pixels
  2. ECG Display format : 4 leads-linked median. 12 leads-median-enlarge-median 12 leads-medians 3*4 + R lead static linked medians + R 12 Dynamic linked medians
  3. Data display : HR, Target HR, BP, stage time, test time, speed, grade, METS, protocol name, protocol stage,e\ STL, STS, Lead disconnected information & patient info. etc.
  4. full discloure: beat-to-beat ECG record
  5. Tread grah:  HR, STL, STS, BR, RPP, Ectopics, R variation jamplitude, workload & running distance.

 PRINTING

  1. Printer : Laser or deskjet
  2. Pepar size : A4 size
  3. print option : Automatic stage, online & offline printing
  4. sweep speed : 5, 12.5, 25, 50 & 100mm/sec
  5. sensitivity : 0.25, 0.5, 1.0, 2.0 & 4.0 cm/mv

CONNECTIVITY

  1. Export format : PDF
  2. Network interface : for file storage. Distribution & E-mail

  STANDARD KIT  :  Treadmill, wireless acquisition unit, patient cable, paper ream, disposable electrodes, user Manual, cardiac stress test software CD, Trolley, Voltage stabilizer

  OPTIONAL  : PC, Printer, UPS for PC